Coating Thickness Gauge NOVOTEST TP-1
 
Portable Coating Thickness Gauge NOVOTEST TP-1 is device for fast non-destructive testing of coating thickness with the highest measurement accuracy
 
Coating thickness gauge is designed to test:
 
thickness of various thick protective coatings on various metals and alloys;
thickness of paint and other dielectrics – radioabsorbing, mastic, teflon, plastic, 
electroplating coatings on steel;
thickness of electroplating and paint coatings on non-ferromagnetic alloys and non-ferrous metals;
thickness of bitumen and other thick coatings on various metals and alloys;
as well as relative humidity, air temperature, surface temperature, dew point temperature and difference between surface and dew point temperatures, estimate the depth of grooves and the surface roughness
 
Electronic thickness gauge is widely used in automotive and other industries for measuring  thickness of paint, testing paint quality, and determining surface conditions of the tested objects.
 
Brochure of Coating Thickness Gauge NOVOTEST TP-1.pdf
 
Advantages
 
 
Wide thickness measurement range
Convenience and ease of operation
Minimum number of controls: one button – one function
Graphical display with backlight
Automatic recognition of probe
Indication of the connected probe type
Control of batteries
 
Specifications
 
Thickness measurement range(depends on probe type) 0 µm … 60 mm
Dimensions, mm 120x60x25
Operating temperature range, ° C -5 … +40 ° C
Batteries 2 AAA
Time of continuous work hours, not less 20
Weight of electronic unit with batteries, no more, kg 0.2
Specifications of probes for Coating Thickness Gauge NOVOTEST TP-1 
Coatings on steel (dielectric and conductive
coatings on ferromagnetic metals and alloys)
 
 Type of probe The coating thickness The measurement accuracy Dimensions of the probe, mm
 
probe F-0, 3 0-300 μm ± (3% ± 1 μm) Ø5×40
probe F-0, 5 0-500 μm ± (3% ± 1 μm) Ø 7×14
probe F-2 0-2000 μm ± (3% ± 2 μm) Ø 9×35
probe F-5 0-5000 μm ± (3% ± 2 μm) Ø 18×35
 
Coating on the non-magnetic metals
 
(Dielectric coatings on non-ferrous metals and alloys)
probe SF-0, 5 0-500 μm ± (3% ± 2 μm) Ø 12×35
probe NF-2 0-2000 μm ± (3% ± 2 μm) Ø 12×35
 
Thick coatings on metals (dielectric coatings on metals)
probe M-12 0-12 mm ± (3% + 0.002 mm) Ø 15×50
probe M-30 1-30 mm ± (3% + 0.003 mm) Ø 40×50
probe M-60 1-60 mm ± (3% + 0.005 mm) Ø 70×60
 
Measurement of surface roughness, Rz
 
(After abrasive blasting pre-painting work)
probe DSH 2-360 μm ± (3% ± 2 μm) Ø 12×45
 
Temperature, humidity and dew point
probe DT -50 … +125 ° C + / – 1 ° C Ø 15×45
probe DTVR Humidity: 0 – 100% Temperature: -50 … 125 °C
Dew point: -15 – +40 °C ± 5%
± 1 ° C
± 2 ° C Ø 15×120
 
 
Available options
 
Additional probes for thickness gauge (depends on requirements)
Batteries
Charger
Set of reference thickness samples
 
Standard package
 
Thickness gauge electronic unit
Probe – 1 pc
Set of reference thickness samples
Batteries (AAA) – 2 pcs
Charger
Operating manual
Case
 
 
Media

 

Coating Thickness Gauge NOVOTEST TP-1. Checking the measurement accuracy